Relative values for Model 204 numeric parameters: Difference between revisions
mNo edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
Prior to the introduction of this feature, <var class="product">Model 204</var> numeric parameter settings are absolute values only, optionally qualified by a leading minus sign (<tt>-</tt>) to indicate a negative value. For example, you might set the value of the LSTBL user table to 50,000 bytes: | Prior to the introduction of this feature, <var class="product">Model 204</var> numeric parameter settings are absolute values only, optionally qualified by a leading minus sign (<tt>-</tt>) to indicate a negative value. For example, you might set the value of the LSTBL user table to 50,000 bytes: | ||
<p class="code">UTABLE LSTBL 50000 </p> | <p class="code">UTABLE LSTBL 50000 </p> | ||
Subsequently, you find that you need to increase the initial setting to 60,000. You can issue <code>UTABLE LSTBL 60000</code>, or as of <var class="product"> | Subsequently, you find that you need to increase the initial setting to 60,000. You can issue <code>UTABLE LSTBL 60000</code>, or as of version 7.5 of <var class="product">Model 204</var> or version 8.0 of the <var class="product">Sirius Mods</var>, you can issue: <p class="code">UTABLE LSTBL 10000+</p> | ||
The plus sign after the setting value above indicates not a new parameter value but a change to the current value: that is, a relative increase of 10,000. An alternative equivalent, which increases the current value by 20%, is: | The plus sign after the setting value above indicates not a new parameter value but a change to the current value: that is, a relative increase of 10,000. An alternative equivalent, which increases the current value by 20%, is: |
Revision as of 20:25, 8 June 2013
Prior to the introduction of this feature, Model 204 numeric parameter settings are absolute values only, optionally qualified by a leading minus sign (-) to indicate a negative value. For example, you might set the value of the LSTBL user table to 50,000 bytes:
UTABLE LSTBL 50000
Subsequently, you find that you need to increase the initial setting to 60,000. You can issue UTABLE LSTBL 60000
, or as of version 7.5 of Model 204 or version 8.0 of the Sirius Mods, you can issue:
UTABLE LSTBL 10000+
The plus sign after the setting value above indicates not a new parameter value but a change to the current value: that is, a relative increase of 10,000. An alternative equivalent, which increases the current value by 20%, is:
UTABLE LSTBL 120%
To decrease the initial setting by 10,000, you can issue either of these relative settings, both of which set LSTBL to 40000:
UTABLE LSTBL 10000- UTABLE LSTBL 80%
No space between the numeric value and the relative value indicator is allowed.
These three indicators — a following plus sign (+), minus sign (-), or percent sign (%) — are the only relative setting indicators. Though they are likely to most commonly used for server table sizes, they are available for all Model 204 numeric parameters; for example:
R SCRNSTBL 4000+
The option to use the relative setting of the parameter may be particularly useful in a dynamic environment where a parameter setting may be subject to change from a variety of code sources and conditions. In this case, explicit settings might become difficult to maintain.