Line 17: Line 17:
<p>SMFSVC applies only to z/OS and z/VM. It can be set or viewed only in z/OS. </p>
<p>SMFSVC applies only to z/OS and z/VM. It can be set or viewed only in z/OS. </p>
<p class="note"><b>Note:</b> Under z/OS, SMFSVC must be APF authorized.</p>
<p class="note"><b>Note:</b> Under z/OS, SMFSVC must be APF authorized.</p>
===Usage===
Obsolete as of Model 204 version 7.5.
As of 7.5, having Model 204 write records to the SMF data set no longer requires the installation of an SVC.
Therefore, the SMFSVC parameter is no longer required and, if present, will be ignored and flagged with the following informational message:
<p class="code">M204.0204: PARAMETER SMFSVC OBSOLETE AND NOT RESET</p>
[[Category:System parameters]]
[[Category:System parameters]]
[[Category:Parameters]]
[[Category:Parameters]]

Revision as of 23:12, 5 November 2013

SMF SVC # (obsolete) (obs)

Summary

Default value
0 (z/OS); 241 (CMS)
Parameter type
System
Where set
On User 0's parameter line (z/OS)
Related products
All
Introduced
Model 204 V6.1 or earlier

Description

The number of the nonprivileged System Management Facility (SMF) SVC

SMFSVC applies only to z/OS and z/VM. It can be set or viewed only in z/OS.

Note: Under z/OS, SMFSVC must be APF authorized.

Usage

Obsolete as of Model 204 version 7.5.

As of 7.5, having Model 204 write records to the SMF data set no longer requires the installation of an SVC.

Therefore, the SMFSVC parameter is no longer required and, if present, will be ignored and flagged with the following informational message:

M204.0204: PARAMETER SMFSVC OBSOLETE AND NOT RESET