SEQOPT parameter: Difference between revisions
(Automatically generated page update) |
mNo edit summary |
||
Line 13: | Line 13: | ||
<dd><var class="product">Model 204 V6.1</var> or earlier | <dd><var class="product">Model 204 V6.1</var> or earlier | ||
</dl> | </dl> | ||
==Description== | ==Description== | ||
<p>The | <p> | ||
<p>SEQOPT must be either zero or 1. If the default value of zero is used, the prefetch feature is disabled. If a value of 1 is specified, the prefetch feature is enabled. </p> | Enables or disables the [[Record_loops#The prefetch (look-ahead_read) feature|prefetch (look-ahead read) feature]].</p> | ||
<p>The prefetch feature can produce performance improvements for applications containing FOR EACH RECORD statements. The prefetch feature is described | <p> | ||
<p>The prefetch feature can also be controlled with the RESET command issued by a user having system manager privileges.</p> | <var>SEQOPT</var> must be either zero or 1. If the default value of zero is used, the prefetch feature is disabled. If a value of 1 is specified, the prefetch feature is enabled. </p> | ||
<p>Use of the prefetch feature requires that the MAXBUF parameter be set large enough to accommodate the look-ahead reads. Without this setting, performance might worsen. The specification for the MAXBUF parameter is calculated by the following formula: | <p> | ||
The prefetch feature can produce performance improvements for applications containing <var>FOR EACH RECORD</var> statements. The prefetch feature is also described in the <var class="book">[http://docs.rocketsoftware.com/nxt/gateway.dll/RKBnew556/model%20204/v7.4/m204_v7r4_system_manager.pdf Rocket Model 204 System Manager's Guide]</var>.</p> | |||
<p> | |||
The prefetch feature can also be controlled with the <var>RESET</var> command issued by a user having system manager privileges.</p> | |||
<p> | |||
Use of the prefetch feature requires that the <var>[[MAXBUF parameter|MAXBUF]]</var> parameter be set large enough to accommodate the look-ahead reads. Without this setting, performance might worsen. The specification for the <var>MAXBUF</var> parameter is calculated by the following formula: </p> | |||
<p class="code">MAXBUF = NUSERS * (4 + 2 * (Maximum FOR EACH RECORD loop nest level) | <p class="code">MAXBUF = NUSERS * (4 + 2 * (Maximum FOR EACH RECORD loop nest level) | ||
</p> | </p> | ||
[[Category:System parameters]] | [[Category:System parameters]] | ||
[[Category:Parameters]] | [[Category:Parameters]] |
Revision as of 17:28, 16 April 2014
Sequential processing options
Summary
- Default value
- 0
- Parameter type
- System
- Where set
- On User 0's parameter line
- Related products
- All
- Introduced
- Model 204 V6.1 or earlier
Description
Enables or disables the prefetch (look-ahead read) feature.
SEQOPT must be either zero or 1. If the default value of zero is used, the prefetch feature is disabled. If a value of 1 is specified, the prefetch feature is enabled.
The prefetch feature can produce performance improvements for applications containing FOR EACH RECORD statements. The prefetch feature is also described in the Rocket Model 204 System Manager's Guide.
The prefetch feature can also be controlled with the RESET command issued by a user having system manager privileges.
Use of the prefetch feature requires that the MAXBUF parameter be set large enough to accommodate the look-ahead reads. Without this setting, performance might worsen. The specification for the MAXBUF parameter is calculated by the following formula:
MAXBUF = NUSERS * (4 + 2 * (Maximum FOR EACH RECORD loop nest level)