IOSLICE parameter: Difference between revisions
Line 19: | Line 19: | ||
<ul> | <ul> | ||
<li> | <li> | ||
Executing a READ SCREEN, READ MENU, or <var>[[$READ|$READ]]</var> statement</li> | Executing a <var>[[Full-screen_feature#READ_SCREEN_statement|READ SCREEN]]</var>, <var>[[Full-screen_feature#READ_MENU_statement|READ MENU]]</var>, or <var>[[$READ|$READ]]</var> statement</li> | ||
<li> | <li> | ||
Requesting I/O to a <var class="product">Model 204</var> file or external sequential file</li> | Requesting I/O to a <var class="product">Model 204</var> file or external sequential file</li> |
Revision as of 15:13, 28 October 2014
CPU slice - IO
Summary
- Default value
- 30
- Parameter type
- System
- Where set
- On User 0's parameter line or reset by system manager
- Related products
- All
- Introduced
- Model 204 V6.1 or earlier
Description
The CPU time slice allotment, in milliseconds, for non-CPU-bound users
This parameter determines which requests are considered CPU-bound. A user request is considered IO-bound unless IOSLICE milliseconds pass without the request voluntarily yielding the CPU. After IOSLICE milliseconds of CPU have been consumed, the user is considered CPU-bound. From this point, if CPUSLICE milliseconds expire without yielding the CPU, the user is time sliced (forced to yield the CPU to the user with the next highest priority).
A user voluntarily yields the CPU by any of the following actions:
- Executing a READ SCREEN, READ MENU, or $READ statement
- Requesting I/O to a Model 204 file or external sequential file
- Going into a wait for a record or resource lock
Decreasing IOSLICE causes more requests to be considered CPU-bound, and increasing it causes fewer requests to be classed as CPU-bound.
Increasing this parameter diminishes the impact of dynamic dispatching, thus allowing CPU-bound requests to monopolize the CPU. Decreasing this parameter heightens the effect of dynamic dispatching, resulting in increased scheduler overhead.
For more information about Model 204 dynamic dispatching, see the Model 204 System Manager's Guide.