LOGIN or LOGON command: Difference between revisions
Line 65: | Line 65: | ||
<var class="term">password</var> is a character string. | <var class="term">password</var> is a character string. | ||
The length of <var class="term">password</var> is: <br /> | The length of <var class="term">password</var> is: <br /> | ||
1 to 8 characters long (Model 204 version 7. | 1 to 8 characters long (Model 204 version 7.6 and earlier) <br /> | ||
1 to 127 characters long (Model 204 version 7. | 1 to 127 characters long (Model 204 version 7.7 and later). </p> | ||
<ul> | <ul> | ||
<li>Without the Password Expiration feature installed, a password cannot contain spaces, commas, or colons. The password gives the user access to the system. </li> | <li>Without the Password Expiration feature installed, a password cannot contain spaces, commas, or colons. The password gives the user access to the system. </li> | ||
Line 72: | Line 72: | ||
<li>With the Password Expiration feature installed, the password cannot contain spaces, commas, or colons, and must: | <li>With the Password Expiration feature installed, the password cannot contain spaces, commas, or colons, and must: | ||
<ul> | <ul> | ||
<li>Be six, seven or eight characters long.</li> | <li>Be six, seven, or eight characters long (Model 204 version 7.6 and earlier), or<br /> | ||
be at least six characters long and up to a maximum of 127 characters (Model 204 version 7.7 or later).</li> | |||
<li>Begin with an alphabetic character.</li> | <li>Begin with an alphabetic character.</li> |
Revision as of 20:03, 7 March 2016
Summary
- Privileges
- Any user
- Function
- Logs in to the Model 204 system
Syntax
{LOGIN | LOGON} userid [account]
Where:
userid | A character string that identifies the user who is logging in to Model 204. The user ID can be 1 to 10 characters in length.
When an external security interface is performing login validation, the range for the user ID might differ. |
---|---|
account | A character string that identifies the account under which the user is logging in to Model 204. The account can be 1 to 10 characters in length. Under an external security interface, the maximum for account might differ.
The account identifies the user account to Model 204's accounting routines. The value of account in these routines might be affected by the use of an external security interface. Refer to the Model 204 Security Interfaces Manual for a detailed discussion of security interfaces. If the login feature is not in use, the string |
Example
In this example, a user logs in to Model 204:
LOGIN BLOOM D0101005 *** M204.0347: PASSWORD BUDGET *** M204.0353: BLOOM D0101005 LOGIN 88 JUL 11 12.04
Usage notes
The LOGIN and LOGON commands allow the user to gain access to Model 204 at most installations. The system manager controls whether or not the login procedure is required at an installation. If the login procedure is not required, the user is assigned a default set of privileges.
Once a user has connected to Model 204, and if the system manager has set the Model 204 option to require logins, any commands entered by the user (other than LOGIN or LOGON) display a request for the user to log in.
Failing to log in correctly
If either the user ID or the password is incorrect, Model 204 displays a message that the login failed. If an error occurs, the user reissues the LOGIN command.
- Model 204 provides login delays for threads that repeatedly fail to log in correctly. Refer to the discussion of this feature in Login delays.
- A password must follow restrictions. At a minimum a password cannot contain spaces, commas, or colons, and must not be the same as the USERID, the current password, or the previous password. Additional restrictions may apply with the Password Expiration feature or be specific to your site. See "Setting a password" below.
- IFSTRT and IFDIAL threads can change the password by appending a colon and the new password, as described above. When the password security feature is installed, the more restrictive password rules apply, except that IFSTRT threads do not require the user to reenter the new password.
Setting a password
After the entry of a LOGIN or LOGON command, the system prompts for a password as follows:
*** M204.0347: PASSWORD password[:new password]
If the Password Expiration feature was installed at your site, the following message is also issued to confirm your password:
M204.2633: RE-ENTER NEW PASSWORD
password is a character string.
The length of password is:
1 to 8 characters long (Model 204 version 7.6 and earlier)
1 to 127 characters long (Model 204 version 7.7 and later).
- Without the Password Expiration feature installed, a password cannot contain spaces, commas, or colons. The password gives the user access to the system.
- With the Password Expiration feature installed, the password cannot contain spaces, commas, or colons, and must:
- Be six, seven, or eight characters long (Model 204 version 7.6 and earlier), or
be at least six characters long and up to a maximum of 127 characters (Model 204 version 7.7 or later). - Begin with an alphabetic character.
- Include at least one numeric character.
- Be six, seven, or eight characters long (Model 204 version 7.6 and earlier), or
new password is governed by the same limitations and requirements as password. However, you can enter a new password at login only if your user privileges include the ability to change your password as you log in.
When a new password is being specified, the password and the new password must be separated by a colon (:). When the user enters the password, Model 204 masks it from view.
After logging in, the user has access to most of the Model 204 system commands. The user ID under which the user logs in determines which privileges are available. These privileges can include the ability to:
- Change the login password
- Change file passwords
- Use restricted commands such as CREATE FILE and MONITOR
- Reset restricted parameters with the RESET command
For information on the login process for an external security interface, refer to the Rocket Model 204 Security Interfaces Manual.