Line 5: | Line 5: | ||
<p class="note"><b>Note:</b> The RSQL and EVCP object files are mutually exclusive. Do not link both into the same load module.</p> | <p class="note"><b>Note:</b> The RSQL and EVCP object files are mutually exclusive. Do not link both into the same load module.</p> | ||
===Relinking RSQL or EVCP=== | ===Relinking with RSQL or EVCP=== | ||
To apply fixes | To apply fixes for an RSQL or EVCP object file, relink the load modules by editing and submitting [[Model 204 RSQL/EVCP link job stream for IBM z/OS|LKRSQLJ]] as follows: | ||
<ol> | <ol> |
Revision as of 21:27, 4 November 2016
Applying RSQL and EVCP fixes
After you download the RSQL and EVCP object files, you have access to LKRSQLJ
, a jobstream to relink the Model 204 load modules (ONLINE, IFAM1, IFAM4) with the new object file.
Note: The RSQL and EVCP object files are mutually exclusive. Do not link both into the same load module.
Relinking with RSQL or EVCP
To apply fixes for an RSQL or EVCP object file, relink the load modules by editing and submitting LKRSQLJ as follows:
- Copy
LKRSQLJ
into a local TSO library. - Edit
LKRSQLJ
for your configuration:- Replace the first line with a JOB card.
- Edit the lines near the top of the jobstream marked with 1-6 followed by
<<
. The numbers correspond to numbered instructions in the comments following those lines. - As needed, edit the lines after
SYSLIN DD *
that are marked with<<
. See the comments at the top of theSYSLIN
section for instructions.
- Submit the
LKRSQLJ
job to relink either the RSQL or EVCP object file with the load module, based on your edits to the code.