M204.0096  Member memberName removed from parallel stream streamName

During parallel stream processing, the member memberName of the stream streamName encountered an error and was removed from further processing.

For output streams, the error was a file full or I/O error. For input streams, the file encountered an I/O error. M204.0096 is not issued for an end-of-data condition on input. If the numbers of members remaining is greater than the MINAVAIL number specified (DEFINE STREAM), processing continues. If not, the appropriate condition is reflected to Model 204.

System manager response: M204.0096 may be accompanied by other messages which further describe what has occurred. Follow instructions described for those messages.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=0Sets batch (single user) return code
CLASS=IInformation class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter
NOTERMDoes not display the message on the user's terminal
OPRWrites the message to the (operator) console