M204.0398
M204.0398 Fatal I/O error on CCARF in pass 2 of roll forward
The second pass of roll forward detected an end of file condition at a different place in the CCARF input stream than was detected in the first pass. This indicates a problem with the media used for the CCARF input stream.
System manager response: The most likely cause of the problem is a hardware error. Try copying the journal to another data set or mounting it on another device, and re-submit the recovery job.
Message attributes:
| RETCODEO=52 | Sets online return code | 
|---|---|
| RETCODEB=52 | Sets batch (single user) return code | 
| CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter | 
| AUDITAD | Writes the message with line type AD to the audit trail | 
| NOCOUNT | Does not increment the error count (ERCNT) parameter | 
| OPR | Writes the message to the (operator) console | 
| SNAP | Generates a CCASNAP for the run | 
| DUMP | Generates a SYSUDUMP for the entire Model 204 region |