M204.1282  Parallel stream token disabled​,​ record token2 is not the same for all members

The different members of parallel stream token are not identical. Record number differs between the different members of the parallel stream. This message is accompanied by message M204.1350 or M204.1894 for each member of the parallel stream. These messages detail the differences found between the members for the specified record.

System manager response: Examine the audit trail, job control language, and additional messages issued by Model 204 or the operating system to determine the cause of the differences. If the stream is used for recovery and only one valid member is available, use the single valid member rather than the parallel stream. Refer to Parallel stream configuration for a description of how to use parallel streams for recovery.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter
NOTERMDoes not display the message on the user's terminal
OPRWrites the message to the (operator) console