M204.1329
M204.1329 User's pushdown list overflowed
The pushdown list (PDL) allocated by the parameter LPDLST has overflowed.
Response: Do one of the following:
- Increase the value of LPDLST using the UTABLE command.
- Notify your system manager.
System manager response: Contact Technical Support. Have the following documentation ready:
- Audit trail
- Snap(s)
- System dump
- User Language request for the user who received the message
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
SAVE | Saves the message in the VIEW ERRORS table |
SNAP | Generates a CCASNAP for the run |
DUMP | Generates a SYSUDUMP for the entire Model 204 region |