M204.1803

From m204wiki
Revision as of 20:38, 12 March 2018 by JAL (talk | contribs) (add <var>'s)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

M204.1803  No inbound threads allocated

Model 204 is processing an OPEN LINK command and detects that no server threads were allocated during Model 204 initialization.

System manager response: If the link being opened is defined with TRANSPORT=IUCV, add IODEV 17 statements to the CCAIN file.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter