M204.1839 Offload PST for ring stream token failed to initialize
The offload process for ring stream token cannot be run as an asynchronous process due to a failure when attempting to attach a Model 204 pseudo subtask. Offloading is performed as a synchronous process using the current user's server.
System manager response: Increase the number of pseudo subtasks that the system can start by raising the value of the NSUBTKS parameter on the User 0 parameter line in the CCAIN input.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |
OPR | Writes the message to the (operator) console |