M204.2106 Stack overflow. Recursion too deep.
The value of the LPDLST parameter is too small to execute the operation that is currently being performed.
Response: It may be possible to complete the operation by simplifying or decreasing the size of the statement or command currently being executed. If the necessary operation cannot be accomplished with the current value of LPDLST, contact the System Manager to increase the value of LPDLST.
This error will be accompanied by a user soft restart.
System manager response: The value of LPDLST can be modified by changing the User 0 parameter line in the Model 204 initialization setup.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=96 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
CANCEL | Cancels the user's request |
COUNT | Increments the error count (ERCNT) parameter |