M204.2167
M204.2167 A close error has been detected on dataset token
z/OS detected an error during execution of the CLOSE for the specified tape data set.
System manager response: Check the JES joblog for an x14
abend and for the accompanying IECxxxx message to determine the cause of the error. The specified tape data set may be unreadable following this error.
Operator response: Notify the System Manager.
Message attributes:
RETCODEO=8 | Sets online return code |
---|---|
RETCODEB=8 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |
OPR | Writes the message to the (operator) console |
SAVE | Saves the message in the VIEW ERRORS table |