LRUTIM parameter
Time to flush obsolete LRU references (obsolete) (obs)
Summary
- Default value
- 0
- Parameter type
- System
- Where set
- On User 0's parameter line
- Related products
- All
- Introduced
- Model 204 V6.1 or earlier
Description
The interval in milliseconds between successive user references to a disk page for references to be considered obsolete
A time of 0 indicates that references should never be considered obsolete. This parameter is used in calculating the DKRR statistic. Refer to Description of statistics for more information about the DKRR statistic.