M204.1295  No audit trail or journaling stream(s)

This error can occur only if the SYSOPT parameter includes the 128 option. Problems with both the audit trail and journal data set(s) result in this error:

  • The CCAAUDIT data set must be defined by appropriate JCL statements (DD, DLBL/EXTENT, FILEDEF).
  • The CCAJRNL stream must be defined in the JCL or via the DEFINE STREAM CCAJRNL command which is inserted in the CCAIN stream prior to the User 0 parameter line.

System manager response: In your JCL or EXEC procedure, supply the CCAAUDIT statement, or if you have already provided one, examine it and check for any causes of an open failure. Do this only if you require an audit trail for the run. Also, include statements for the CCAJRNL (or the correct DEFINE STREAM command) if you want roll forward information to be logged to the journal data set. Rerun Model 204.

Operator response: Contact your system manager.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter
NOTERMDoes not display the message on the user's terminal
OPRWrites the message to the (operator) console