M204.1922

From m204wiki
Revision as of 17:34, 7 March 2018 by DmeWiccan (talk | contribs) (Automatically generated page update)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

M204.1922  CFRJRNL set to 0 because CFRLOOK​=​0

At initialization time, parameter CFRLOOK was set equal to 0 or was not specified and CCAJRNL was set to 1. This message is sent both to the audit trail and the operator.

System manager response: This is an informational message; the run continues with CCAJRNL reset to 0. See the Rocket Model 204 System Manager's Guide for an explanation of parameter settings.

Operator response: Notify the system manager.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=0Sets batch (single user) return code
CLASS=IInformation class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter
AUDITADWrites the message with line type AD to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter
OPRWrites the message to the (operator) console