M204.2005
M204.2005 token missing or invalid token2 token3
Model 204 in a z/VM environment must connect to a GCS machine for SNA Communications Server (formerly VTAM) connectivity, and the GCS machine ID is missing or invalid. This message has two forms:
- VTGCSSRV IS MISSING OR INVALID
Model 204 is attempting to initialize full screen SNA Communications Server threads, IODEV=7, and the parameter VTGCSSRV is not set.
- GCSID IS MISSING OR INVALID FOR LINK linkname
Model 204 is attempting to open a LINK that is defined with TRANSPORT=VTAM, and the DEFINE LINK parameter GCSID is not set.
System manager response: Add VTGCSSRV to the Model 204 User 0 parameters, or add a GCSID parameter to the DEFINE LINK command.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |