M204.2049 Position lost during evaluation or it was never declared
The POSITION could not be found in GTBL during evaluation. It was removed from GTBL with the CLEAR statement during evaluation, or it was never declared with the REMEMBER statement.
Response: Change the placement of any CLEAR statements so they do not remove POSITIONS from GTBL until it is okay to do so, and make sure there is a REMEMBER statement with the position name.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |
ECHO | Displays the line that caused the error |