M204.2144

From m204wiki
Revision as of 21:33, 26 March 2018 by JAL (talk | contribs) (remove 0 from token0)
Jump to navigation Jump to search

M204.2144  token diagnostic DUMP of MRFT

This message is produced during media recovery (the REGENERATE command) when a diagnostic zap provided by Technical Support has been applied. The message is issued first with token replaced by STARTING. The diagnostic dump is then produced in a series of M204.2145 messages. This M204.2144 message is then issued again with token0 replaced by END OF.

System manager response: Save the audit trail produced by the job, and contact Technical Support.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=0Sets batch (single user) return code
CLASS=IInformation class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter