AMPSUBS parameter

From m204wiki
Revision as of 14:38, 19 April 2013 by DmeWiccan (talk | contribs) (Automatically generated page update)
Jump to navigation Jump to search

Summary

Default value
None
Parameter type
System
Where set
On User 0's parameter line or reset by system manager
Related products
All
Introduced
Model 204 V6.1 or earlier

Description

The number of active subtasks in a Model 204 multiprocessing online configuration (IBM z/OS systems only)

The value of AMPSUBS must be less than or equal to the value of the NMPSUBS parameter, which determines the number of subtasks attached during initialization. The AMPSUBS parameter allows the system manager to adjust the number of active offload subtasks without bringing down the online.

If AMPSUBS is less than NMPSUBS, the extra subtasks remain attached but do not perform offloaded work. If AMPSUBS is set to 0, the main task performs all the work and multiprocessing is effectively turned off.

For more information about tuning MP, refer to the Rocket Model 204 System Manager's Guide.