Debugger Client Beta documentation
Introduction
This page describes any beta versions of the Janus/TN3270 Debugger Workstation Client that are available.
Build 63, Tag 1 Beta
Run Until, White lists, Black lists with Daemons
When used with Model 204 Version 7.6 and higher, Client Build 63 extends to
sdaemon threads the procedure-name matching for Run Until, White List, and Black List processing that formerly ran only at the main/master thread level. For example, runUntil desiredProc
now stops if a Daemon thread includes the desiredProc procedure.
HTTP PAC file URLs
The Janus Debugger Client supports Proxy Auto Config (PAC) files, providing a method to control which web requests are routed through the Janus Debugger Client when the Internet Explorer (IE) browser is used.
IE references PAC files
with a URL. Prior to Build 63 of the Debugger Client, the Client supported only file-mode URLs (file://
), so the PAC files it generated had to be stored on the local file system of the workstation running the Client. As of its version 11, IE is deprecating the use of file URLs for PAC files and wants HTTP (http://
) URLs to be used. Eventually file URLs will not be supported at all, hence the need for the Client to use an HTTP URL.
The client has been modified to upload the PAC files generated in the existing "New Pac" or "Merged Pac" modes to an HTTP server. It had also been modified to set the PAC URL in IE to an HTTP-style URL that points to the PAC that was generated and uploaded.
HTTP Server requirements/setup for PAC files
Before changing Client settings, you must provide an HTTP (Web) server to hold the PAC files. Any web server that supports HTTP PUT and GET may be used. This document provides an example of how to set up a Janus Web Server to handle HTTP-based PAC files. Note that the PAC files are temporary: when the Client starts, a new PAC is generated and uploaded. This prevents the problem of HTTP PAC files being out of date, since they are based on workstation-based configuration files which can change at any time.
The following SOUL program takes one command line argument, a TCP/IP port number, and creates a Janus Web server for uploading and serving PAC files:
begin variables are undefined local subroutine closeFile(%iFile is string len 8 input) * Close the file whose name is passed. Messages surpressed. %rc is float $resetn('MSGCTL', 6, %rc) $close('FILE ' with %iFile) $resetn('MSGCTL', 0, %rc) end subroutine local function openFile(%iFile is string len 8 input) is float * Open the file whose name is passed and return 0 for success or * non-zero for failure. Messages surpressed. %rc is float $resetn('MSGCTL', 6, %rc) openc file %iFile $resetn('MSGCTL', 0, %rc) return $status end function * Get and validate the command line argument: port number %args is object stringlist %args = %(system):arguments:unspace:parseLines(', ') %portNumber is float if (%args:count eq 0) then print 'No port number specified' stop elseif (%args:count > 1) then print 'Too many arguments' stop elseif (%args(1) is not like '/2-5(#)') then print 'Invalid port number' stop else %portNumber = %args(1) end if %pacRepo is string len 8 initial('JDPACREP') %worker is object daemon auto new %workForDaemon is object Stringlist auto new * See if the memory file for a PAC repository is there, if not create it if (%(local):openFile(%pacRepo) eq 0) then printText Memory file {%pacRepo} already present %(local):closeFile(%pacRepo) else printText creating memory file {%pacRepo} text to %workForDaemon = new ALLOCATE {%pacrepo} WITH MEMORY PAGES=300 CREATE {%pacrepo} PARAMETER BSIZE=1, DSIZE=250 END OPENC {%pacrepo} IN {%pacrepo} INITIALIZE CLOSE {%pacrepo} end text %worker:run(%workForDaemon):print end if * Set up a simple Janus web server with web rules for loading * serving and listing PAC files generated bythe debugger client. %portName is string len 8 initial('JDPACSRV') * Get rid of any earlier one, so this script can be rerun as needed text to %workForDaemon = new JANUS DRAIN {%portName} JANUS DELETE {%portName} end text %worker:run(%workForDaemon) * Create the server and its rules text to %workForDaemon = new * Create a web server JANUS DEFINE {%portName} {%portNumber} WEBSERV 20 TRACE 7 * Allow upload of PAC files via HTTP PUT of a URL of format /pacman/xxx.js JANUS WEB {%portName} ON PUT /PACMAN/*.JS OPEN FILE {%pacRepo} RECV *.JS BASE64 JANUS WEB {%portName} ALLOW PUT /PACMAN/*.JS * Provide HTTP GET access for URLs of format /pacman/xxx.js JANUS WEB {%portName} ON GET /PACMAN/*.JS OPEN FILE {%pacRepo} - SEND *.JS BINARY EXPIRE +0 * Start the web server JANUS START {%portName} end text %worker:run(%workForDaemon):print end
Since the PAC files are temporary, they are stored in a memory file (not persistent between runs). This also means that this procedure does not need any disk files, DD cards, etc. The PAC files are stored as Model 204 procedures. The PAC file procedures created by the Client (see the following sections), have names based on the IP number of the Client workstation to avoid conflicts.
DebuggerConfig.xml changes
Once the HTTP server is set up to accept and serve PAC files, the Debugger Client configuration must be updated to identify it. This is done with the new httpPacURL tag in the debuggerConfig.xml file:
<debuggerConfig version="1.0"> <httpPacURL>http://pacServerHost:pacServerPort/pacman</httpPacURL>
Where:
- pacServerHost is the host name or IP number of the PAC Janus Web Server described above.
- pacServerPort is the port number passed the to SOUL program shown above.
When the Debugger Client is started, and httpPacURL
is specified in the configuration, it is validated.
Validation consists of HTTP PUT and GET of a test file. If there is a problem with httpPacURL, an error is displayed in the Audit tab.
Preferences UI changes
Once the server has been set up and the client configuration includes httpPacURL
, you enable the HTTP Pac feature through user preferences:
- Start the client.
- Select
File > preferences
. - Select
newPac
ormergedPac
for an IE Mode; this enables the PAC Options button. - Click the PAC Options button, and the PAC Options dialog is presented.
- Select
file://
orhttp://
mode for the PAC URL.
As an alternative, you can use the setIEMode command, which is enhanced to support this feature.
SetIeMode command changes
If a setIEMode command specifies a PAC mode (newPac or mergedPac), you may
specify file
or http
to control which type of PAC URL is used. file
is the default:
setIeMode {none|proxy|newPac|mergedPac} [file|http]
ShowIE command changes
ShowIE output has been enhanced to display URL info for any PAC file in use by the Debugger Client. For example:
Current ie mode: mergedPac Current ie settings ...Proxy flags=(5) ...Proxy server=() ...Proxy bypass=() ...Proxy autoConfigUrl=(http://pacServerHost:pacServerPort/pacman/PAC.10.111.2.82.JS) ...Raw flag byte=(05) ...Read from registry key=(HKEY_CURRENT_USER\Software\Microsoft\Windows\CurrentVersion\Internet Settings) Generated New Pac file: c:\debugger\stateFiles\debuggerInternalPac.js Added: 54 web servers from the configuration. Generated Pac File: Pac file shown here pacURLMode: http <== New line httpPacUrl='http://pacServerHost:pacServerPort/pacman/' <== New line httpPac upload filename: 'PAC.10.111.2.82.JS' <== New line
RetryHTTPPac command
If you have an error on the validation of the HTTP PAC server when you bring up the client, and then fix the HTTP Server, you can issue the RetryHTTPPAC command from the client as an alternative to restarting the client.
&¤tPacFile function added
The &¤tPacFile function returns the URL of the PAC file in use or ""
if none. The URL returned could be either a file:
or http:
URL.
Command: echo &¤tPacFile Macro message: http://pacServerHost:pacServerPort/pacman/PAC.10.111.2.82.JS
Other new commands
As part of developing and testing the HTTP URL support, three additional commands were added which may also be of general use:
httpPutFile file url
— Do an HTTP PUT file upload for the file and URL specifiedhttpPutString string url
— Do an HTTP PUT file upload for the string and URL specifiedhttpGet file url
— Do an HTTP GET for the URL specified, display in console