M204.0020  variousMessages

This message is generic and is used mainly for informational messages. The possible messages, in bold face type, are as follows:

PROPRIETARY MESSAGES
IGCLM244 VERSION =
SUBSYSTEM NAME =

No action needed - informational only

IGCLM244 LOAD FAILED

IGCLM244 must be contained within STEPLIB, JOBLIB or LPA.

INVALID M204XSVC FOUND(linked|xxx) - version date

The M204SVC must match the version of Model 204 that is running. Either an incorrect SVC was linked into Model 204 or the CCAIN parameter XMEMSVC=xxx specified an incorrect SVC number. The version and date of the found SVC are listed.

SUBSYSTEM NAME ABSENT

No subsystem name was specified within IGCLM244. Use CRAMGEN to relink IGCLM244 with an appropriate subsystem name.

CRAM SYSTEM LX FAILED

A stand-alone cross memory environment was attempted and failed. Either an LX was not available or a GETMAIN failed.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=0Sets batch (single user) return code
CLASS=IInformation class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter
AUDITADWrites the message with line type AD to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter
NOPREFIXSuppresses the M204. or MSIR. message prefix

Back to list of messages