M204.0027

From m204wiki
Revision as of 00:12, 13 February 2018 by DmeWiccan (talk | contribs) (Automatically generated page update)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

M204.0027  Aux procedure dictionary full

When Model 204 performs a subsystem initialization, the subsystem procedure file is scanned twice. The first scan retrieves the number of subsystem procedures in order to allocate the subsystem's in-core procedure dictionary. The second scan retrieves the procedure information that is copied into the in-core procedure dictionary. This error occurs when another user adds a new subsystem procedure between the first procedure file scan and the second.

Response: Reissue the subsystem command.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter

Back to list of messages