M204.0197
M204.0197 Invalid NOTERM value
NOTERM is a user parameter that specifies the number of IODEV cards or the number of terminal connections in the Model 204 Online job. For IODEV 7 or 37 threads, the parameter NOTERM is set on the first IODEV parameter statement. If the value of NOTERM is missing or a negative number, or if NOTERM is set to some other value on an IODEV statement other than the first IODEV statement, this message will appear.
E 80 80 AUDITAD NOTERM
Message attributes:
RETCODEO=80 | Sets online return code |
---|---|
RETCODEB=80 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |