M204.0377  Insufficient table space to process request

You attempted to add or change a password table entry using the LOGCTL A or LOGCTL C command, but the in-core copy of the password table is not large enough to process the command. The amount of space allocated during initialization for updates to the password table is determined by the value of the LOGADD parameter. Refer to the Login security discussion of the LOGADD parameter.

System manager response: You must rerun Model 204 and retry the command to update successfully. The value of LOGADD must be greater than zero or no updates to the password table are allowed.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter

Back to list of messages