M204.0398  Fatal I​/​O error on CCARF in pass 2 of roll forward

The second pass of roll forward detected an end of file condition at a different place in the CCARF input stream than was detected in the first pass. This indicates a problem with the media used for the CCARF input stream.

System manager response: The most likely cause of the problem, is a hardware error. Try copying the journal to another data set, or mounting it on another device, and re-submit the recovery job.

Message attributes:

RETCODEO=52Sets online return code
RETCODEB=52Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITADWrites the message with line type AD to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter
OPRWrites the message to the (operator) console
SNAPGenerates a CCASNAP for the run
DUMPGenerates a SYSUDUMP for the entire Model 204 region