M204.0503
M204.0503 INVALID TERMBUF SPECIFICATION This message was removed at 7.6 and is no longer applicable in later versions.
This message is issued during initialization (IODEV processing) when the TERMBUF parameter is set incorrectly. Model 204 is terminated. TERMBUF should be between 1 (the default) and the value of NOTERM for the line group.
System manager response: Correct TERMBUF in the CCAIN input and rerun Model 204.
Message attributes:
| RETCODEO=0 | Sets online return code |
|---|---|
| RETCODEB=4 | Sets batch (single user) return code |
| CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
| AUDITMS | Writes the message with line type MS to the audit trail |
| NOCOUNT | Does not increment the error count (ERCNT) parameter |