M204.0732

From m204wiki
Revision as of 13:54, 25 February 2018 by DmeWiccan (talk | contribs) (Automatically generated page update)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

M204.0732  Format error

A HALT command is being processed and the text specified for the message or reply field of the HALT message is not equal to the length specified. This message is followed by a COMMAND REJECTED message. If an IF/THEN statement in SOUL is being processed, the statement has incorrect syntax. Compilation continues but the request is not executed.

Response: If an IF/THEN statement produces the message, correct the syntax and retry the request.

System manager response: If a HALT command produces the message, recalculate the length or change the text in the MESSAGE or REPLY field to conform to the length specified. Then retry the command.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter

Back to list of messages