M204.0806
M204.0806 ENQCTL invalid argument - token
The system operator has entered the ENQCTL command with invalid or missing arguments. The correct format is:
ENQCTL filename sysid jobname stepname date time
The attributes following ENQCTL
represent optional parameters.
Refer to ENQCTL command and How Model 204 resolves locking conflicts for more information. Be careful with this command, as errors may result in a loss of data integrity.
Operator response: Consult with the system manager if you have questions.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |
OPR | Writes the message to the (operator) console |