M204.0931

From m204wiki
Revision as of 14:33, 25 February 2018 by DmeWiccan (talk | contribs) (Automatically generated page update)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

M204.0931  Unable to allocate subsystem control block

This message is issued when Model 204 attempts to initialize a subsystem and there is insufficient memory for the creation of in-core subsystem control blocks.

Response: Notify the system manager.

System manager response: Increase the value of the SPCORE parameter, or decrease MAXBUF in the Model 204 initialization parameters, to ensure that enough space is available to initialize a subsystem.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter
SAVESaves the message in the VIEW ERRORS table

Back to list of messages