M204.0931
M204.0931 Unable to allocate subsystem control block
This message is issued when Model 204 attempts to initialize a subsystem and there is insufficient memory for the creation of in-core subsystem control blocks.
Response: Notify the system manager.
System manager response: Increase the value of the SPCORE parameter, or decrease MAXBUF in the Model 204 initialization parameters, to ensure that enough space is available to initialize a subsystem.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |
SAVE | Saves the message in the VIEW ERRORS table |