M204.0955

From m204wiki
Revision as of 14:37, 25 February 2018 by DmeWiccan (talk | contribs) (Automatically generated page update)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

M204.0955  IFAM2 CRAM open error RC​=​token​,​ IFAM halted - channel ​=​ chanName

An attempt has been made to open a channel that is already open.

This error could also occur if XMEMOPT=X'8X' has not been specified and the system has been configured to use XDM CRAM.

Response: Contact the system manager.

System manager response: The most common reason for a CRAM open failure is using a CRAM channel name that is already open. This can happen if there are multiple copies of Model 204 running in the same system. Review the error codes listed with message M204.0956. If the problem persists, contact Technical Support and have the following information available:

  • Snap
  • Audit trail

Operator response: Issue the IFAMOPEN command to recover.

Message attributes:

RETCODEO=80Sets online return code
RETCODEB=80Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter
NOTERMDoes not display the message on the user's terminal
OPRWrites the message to the (operator) console
SAVESaves the message in the VIEW ERRORS table

Back to list of messages