M204.1057
M204.1057 token out of token2 input buffers are active
This is an informational message generated by the MONITOR command. It indicates the current input buffer usage for the access method specified in the MONITOR command. The information is both displayed and written to the audit trail. This information is not an average but rather a "snapshot" of the current input buffer usage.
System manager response: Use this information for tuning your Model 204 Online system. If the percentage of active input buffers is consistently high, you should increase the number of input buffers. This is done by resetting the TERMBUF parameter in the User 0 CCAIN parameter line.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=0 | Sets batch (single user) return code |
CLASS=I | Information class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |