M204.1107
M204.1107 No statistics in run - MONITOR command invalid
You issued a MONITOR command but the statistics module (STAT) was not link-edited into the Model 204 load module, such as ONLINE or BATCH204, being used.
In recent versions of Model 204, STAT is linked in by default, so this message will not appear.
System manager response: Relink the affected Model 204 module with STAT included, possibly using the relink job LKRELNKJ in the Model 204 RKOBJLIB object library.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |