M204.1309
M204.1309 Journalling terminated, run cancelled
This message applies only if the SYSOPT (system options) value includes option 128. There have been problems writing to the journal data set(s). The formatting of the audit trail is also disabled.
System manager response: Refer to your CCAAUDIT output or console log for more specific messages relating to the I/O error(s). Correct and rerun Model 204. If there are no further messages to assist you, contact Technical Support and have the following documentation ready:
- Audit trail
- Snap dumps, if any
- Console log, if possible
Operator response: Contact your system manager.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |
OPR | Writes the message to the (operator) console |