M204.1324
M204.1324 Block of length token read from token2 contains a record at offset token3 with a record descriptor word which specifies a length of token4
For this variable-length data set, the length of the specified record is not consistent with the length in the record descriptor word (RDW).
System manager response: Verify the record length that you have specified for the named data set. Make sure you have added four bytes (for the record descriptor word) to the maximum record length. Correct the error and rerun Model 204 if the data set is crucial to the run.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |