M204.1342

From m204wiki
Revision as of 04:34, 1 March 2018 by DmeWiccan (talk | contribs) (Automatically generated page update)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

M204.1342  Unable to run CCASYS procedure: token

This message is issued if an error occurs when Model 204 tries to include one of the CCASYS procedures used to control the application subsystem facility. An additional explanatory message may be produced.

The error may occur for the following reasons:

  • Compilation errors have occurred.
  • One or more server tables is too small.
  • GTBL is full.
  • The attention key was pressed.

Response: Check that the server tables are at least as large as the sizes listed in the description of message M204.1457.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter

Back to list of messages