M204.1380
M204.1380 Invalid NOTERM or POLLNO value
The value of the NOTERM parameter or POLLNO parameter on this user parameter line in CCAIN was missing or was not set to the correct number. Model 204 is terminated.
System manager response: Examine the first IODEV statement of the type preceding the message. This entry must specify the total number of IODEVs (NOTERM) of that type. The POLLNO parameter of this first IODEV statement must have 'POLLNO=1'. The following POLLNO parameters must be specified in ascending order. Once set, the value of NOTERM may not be changed for that particular group of IODEV statements. Correct and rerun Model 204.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |