M204.1390
M204.1390 Permanent terminal I/O error - token
A permanent terminal I/O error occurred for the terminal named in the message. The SNA Communications Server (also known as VTAM) start/stop interface cannot recover from the error. The user is restarted.
System manager response: Try the following possible solutions:
- Examine the log message at the termination of the online run for SNA Communications Server sense code information.
- Try the terminal device with another application.
- Ask the system operator if any SNA Communications Server messages appeared on the console.
- Confer with the SNA Communications Server systems programmer about possible causes of error.
Operator response: Notify the system manager.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |
OPR | Writes the message to the (operator) console |
SAVE | Saves the message in the VIEW ERRORS table |