M204.1409
M204.1409 Missing stopping point for file token
This message applies only to a media recovery run. The stopping point for recovering the specified file is missing from the journal data set(s). Model 204 will deactivate the file and attempt to continue processing any other files in the regeneration run.
File manager response: Make sure you specified the correct stopping point on the REGENERATE command. If specifying an exact stopping point, match the date and time against the date and time of the end of the desired update unit as shown in
the audit trail from the original run. If no audit trail is available, create one by running AUDIT204 against the corresponding journal, or specify an inexact stopping point using the LAST UPDATE/CHECKPOINT BEFORE date time
syntax of the REGENERATE command. Also, verify that the journal containing the desired stopping point is included as part of CCAGEN.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |