M204.1707  Sort​/​hash key must be first field loaded into new record

The X'8000' mode bit has been set on a file load control statement to indicate that the field being loaded should begin a new record. The file being loaded is sorted or hashed and the field being loaded is not the sort/hash key.

  • If the file is defined as sort/hash key required (FILEORG X'02' bit is on), the sort/hash key must begin each new record.
  • If the file is defined as sort/hash key not required (FILEORG X'02' bit is off), each record must begin with the sort/hash key, or, if the sort/hash key will be omitted from the record, the field that begins the record must be loaded with the additional mode bit X'2000'.

File manager response: Correct the fast load control statements, and resubmit the job.

System manager response: Contact the file manager.

Operator response: Contact the file manager.

Message attributes:

RETCODEO=24Sets online return code
RETCODEB=24Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter