M204.1788
M204.1788 Unable to allocate necessary process-to-process data areas
The memory for buffers and/or control blocks necessary for the process-to-process communication link could not be allocated. Each link requires additional main storage memory in the Model 204 nucleus region and in the partner process region (for example, CICS, CMS, TSO).
Response: Contact your system manager.
System manager response: If a lack of free storage in the Model 204 nucleus region is the cause of the problem, then increase the SPCORE parameter in the User 0 parameter line. If a lack of free storage in the partner process region (that is, CICS, CMS or TSO) is the cause of the problem, increase the storage using the method applicable to that particular environment.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |
SAVE | Saves the message in the VIEW ERRORS table |