M204.1832
M204.1832 File skewed for different device type, file: token
One or more of the data sets that comprise the Model 204 file token0 have been moved to a different direct access device, and a utility other than Model 204 DUMP/RESTORE was used to move the data. The device on which they now reside requires a skewing factor different than the one for the device on which the file was created. The file cannot be opened.
Response: Contact the system manager.
System manager response: The data set(s) in question must be moved back to a device of the same type as the one on which they were created (using a utility other than DUMP/RESTORE). It will then be possible to OPEN the file and safely move it to a new location with a Model 204 DUMP/RESTORE.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |