M204.1866
M204.1866 I/O error occurred while token CCASTAT dataset
An I/O error has occurred while reading from or writing to the disk copy of the password table (CCASTAT data set). This situation may be caused by a hardware error or because of no more space in the data set (writing only). In either case, the current CCASTAT data set is no longer usable.
Response: Inform your system manager as soon as possible.
System manager response: Determine the cause of the error. If the cause is a hardware problem, shut down Model 204, solve the hardware problem, and rerun Model 204. If the cause is a lack of space for the data set, increase the size of the data set, restore the backup copy of the data set, and rerun Model 204.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |