M204.1867

From m204wiki
Revision as of 17:30, 7 March 2018 by DmeWiccan (talk | contribs) (Automatically generated page update)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

M204.1867  Unable to reposition the CCASTAT dataset to the beginning of the dataset

While updating the CCASTAT data set, Model 204 cannot reposition the pointer back to the beginning of the data set. The most likely cause of this problem is a hardware problem. Any update information entered just prior to the display of this error message will not be recorded in the data set (disk copy of password table).

Response: Inform your system manager as soon as possible.

System manager response: If the update information must be recorded into the disk version of the CCASTAT data set as soon as possible, shut down Model 204, resolve the hardware problem, rerun Model 204, and reenter the update information. Otherwise, the in-core copy of the password table can be used for the current session, and the hardware problem can be resolved at a more convenient time.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter

Back to list of messages