M204.1944  IUCV connection with security machine severed

This user ID was waiting for an IUCV reply from the Security service machine, but the Security service machine severed the IUCV connection. No message exists to receive, and the user ID's security request cannot be authorized. Model 204 terminates.

Response: Contact the system manager.

System manager response: Contact the security officer or check the Security service machine to determine why the Security service machine severed the IUCV connection. Possible explanations are:

  • A FORCE or EOJ command was entered on the Security service machine console.
  • An IUCV error occurred in the Security service machine.
  • The Security service machine was re-IPLed.

Operator response: Contact the system manager.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
CANCELCancels the user's request
COUNTIncrements the error count (ERCNT) parameter
OPRWrites the message to the (operator) console
SAVESaves the message in the VIEW ERRORS table

Back to list of messages