M204.1950
M204.1950 Password must be specified
The conversation requires that a password be specified on the Open Process statement for verification at the remote destination.
Response: Consult with the Model 204 system manager regarding the password requirement
System manager response: Verify that the DEFINE PROCESS command is correct. If so, supply the application with the correct password for the remote destination.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |
SAVE | Saves the message in the VIEW ERRORS table |