M204.1525
M204.1525 No inbound threads available
Model 204 is attempting to honor a request by a remote partner to open an inbound local process, but there are currently no IODEV 19, 27, or 49 threads available on which to run the process. The remote partner will receive a retryable remote allocation failure indication.
System manager response: Whenever this error occurs, a remote process is failing in an attempt to establish a conversation with the local Model 204 because all IODEV 19, 27, or 49 threads are in use for inbound conversations. If this happens frequently you may wish to increase the number of IODEV for your thread type.
Operator response: Contact your system manager.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |
OPR | Writes the message to the (operator) console |
SAVE | Saves the message in the VIEW ERRORS table |