M204.1700
M204.1700 UNIQUE fields are not allowed in files created before Release 9.0
The UNIQUE attribute has been specified for a field being defined with the DEFINE FIELD or REDEFINE FIELD command in a file that was created prior to Release 9.0 (circa 1990) of Model 204. Because UNIQUE fields require the Ordered Index feature, this is not allowed.
File manager response: If UNIQUE fields are wanted, the file must be re-created and re-loaded under Release 9.0 or a later release of Model 204.
System manager response: Contact the file manager.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |