M204.2515

From m204wiki
Revision as of 17:27, 13 March 2018 by DmeWiccan (talk | contribs) (Automatically generated page update)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

M204.2515  token data set is invalid for token2

The data set specified did not contain the correct type of records for the function desired. For instance, a messages data set may have been specified for CCARF, or perhaps a CCAJRNL data set was specified for UTILJ, but all messages were previously written to CCAJLOG.

Response: Specify the correct type of data set for the requested function.

  • AUDIT204 requires a messages type data set for input.
  • REGEN and RESTART require a recovery type data set for input.


Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter
OPRWrites the message to the (operator) console

Back to list of messages